Engineer
Posted 18 Aug 2026
Advertised as “Lead Engineer, Data Center - Memphis”
BranchFactor Summary
The original posting with the fluff stripped out
- Expected experience
- 10+ yrs
- Management level
- People management
- Employment
- On-Site
No salary listed for this role.
Field of studyComputer Engineering, Electrical Engineering, Engineering, Physics (or related)
Study levelBachelor's
SpaceX was founded under the belief that a future where humanity is out exploring the stars is fundamentally more exciting than one where we are not. Today, SpaceX is actively developing the technologies to make this possible, with the ultimate goal of making life multiplanetary and expanding consciousness to the stars.
SpaceXSI is building Super Intelligence to help humanity understand the universe. Our teams are building the full Super Intelligence stack: from our Colossus supercomputers, to Grok models, to our suite of applications, including Grok Bot, Grok Build, Grok Imagine, Grok Voice, and X. We're creating a powerful flywheel where more compute trains better models, better models power more useful products, and what we learn from people using those products shapes what we build next.
ABOUT THE ROLE:
Join the High Power Engineering team supporting SpaceXSI to design, build, operate, and maintain electrical infrastructure for AI training campuses. As a Lead Engineer for Data Center electrical, you will work with a small on-site team to scale high-capacity power systems on a schedule set by compute demand. The position is based in Memphis, TN, with potential travel to other sites.
RESPONSIBILITIES:
- Own the electrical architecture from the medium-voltage bus to the GPU rack — topology, redundancy, and standards — for halls scaling with AI compute load.
- Set and defend the redundancy basis; prove split-feed and cross-feed schemes against bus-fault, transformer-loss, and switchgear-loss contingencies.
- Establish the campus electrical design standard: equipment tagging, drawing conventions, approved vendor list, insulation coordination, grounding, and arc-flash boundaries.
- Own the interface with the compute organization on rack density, step-load behavior, power-capping strategy, and actual-versus-nameplate utilization.
- Own the interface with mechanical and cooling engineering on CDU, sidecar, and pump electrical loads and their contribution to hall demand.
- Lead design reviews with EPCs, OEMs, and owner's engineers; approve vendor drawings and factory acceptance test procedures.
- Direct Design, Commissioning, R&D, BIM/Designer, and Protection & Controls engineers on the Data Center team as those seats fill.
- Collaborate with Transmission & Distribution and Battery Storage leads so hall design, interconnection, and storage dispatch stay on one model of record.
- Ensure compliance with NFPA 70, 70B, 70E, NESC, and IEEE standards, prioritizing safety and engineering excellence.
BASIC QUALIFICATIONS:
- Bachelor's degree in electrical engineering, computer engineering, physics, or another engineering discipline.